Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathcves.json
474 lines (474 loc) · 31 KB
/
cves.json
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
[
{
"id": "CVE-2015-7273",
"description": "Dell Integrated Remote Access Controller (iDRAC) 7/8 before 2.21.21.21 has XXE.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2015-7273",
"_path": "./cvelist/2015/7xxx/CVE-2015-7273.json"
},
{
"id": "CVE-2015-7270",
"description": "Dell Integrated Remote Access Controller (iDRAC) 6 before 2.80 and 7/8 before 2.21.21.21 allows directory traversal.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2015-7270",
"_path": "./cvelist/2015/7xxx/CVE-2015-7270.json"
},
{
"id": "CVE-2015-7275",
"description": "Dell Integrated Remote Access Controller (iDRAC) 6 before 2.85 and 7/8 before 2.30.30.30 has XSS.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2015-7275",
"_path": "./cvelist/2015/7xxx/CVE-2015-7275.json"
},
{
"id": "CVE-2015-7271",
"description": "Dell Integrated Remote Access Controller (iDRAC) 7/8 before 2.21.21.21 has a format string issue in racadm getsystinfo.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2015-7271",
"_path": "./cvelist/2015/7xxx/CVE-2015-7271.json"
},
{
"id": "CVE-2015-7272",
"description": "Dell Integrated Remote Access Controller (iDRAC) 6 before 2.80 and 7/8 before 2.21.21.21 allows attackers to cause a denial of service (buffer overflow) or possibly have unspecified other impact via a long SSH username or input.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2015-7272",
"_path": "./cvelist/2015/7xxx/CVE-2015-7272.json"
},
{
"id": "CVE-2015-7274",
"description": "Dell Integrated Remote Access Controller (iDRAC) 6 before 2.80 allows remote attackers to execute arbitrary administrative HTTP commands.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2015-7274",
"_path": "./cvelist/2015/7xxx/CVE-2015-7274.json"
},
{
"id": "CVE-2020-5344",
"description": "Dell EMC iDRAC7, iDRAC8 and iDRAC9 versions prior to 2.65.65.65, 2.70.70.70, 4.00.00.00 contain a stack-based buffer overflow vulnerability. An unauthenticated remote attacker may exploit this vulnerability to crash the affected process or execute arbitrary code on the system by sending specially crafted input data.",
"baseScore": 7.0,
"baseSeverity": "High",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-5344",
"_path": "./cvelist/2020/5xxx/CVE-2020-5344.json"
},
{
"id": "CVE-2020-5366",
"description": "Dell EMC iDRAC9 versions prior to 4.20.20.20 contain a Path Traversal Vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability by manipulating input parameters to gain unauthorized read access to the arbitrary files.",
"baseScore": 7.1,
"baseSeverity": "High",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-5366",
"_path": "./cvelist/2020/5xxx/CVE-2020-5366.json"
},
{
"id": "CVE-2020-26198",
"description": "Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim\u2019s browser by tricking a victim in to following a specially crafted link.",
"baseScore": 6.1,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-26198",
"_path": "./cvelist/2020/26xxx/CVE-2020-26198.json"
},
{
"id": "CVE-2024-22428",
"description": "\nDell iDRAC Service Module, versions 5.2.0.0 and prior, contain an Incorrect Default Permissions vulnerability.\u00a0It may allow a local unprivileged user to escalate privileges and execute arbitrary code on the affected system. Dell recommends customers upgrade at the earliest opportunity.\n\n",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-22428",
"_path": "./cvelist/2024/22xxx/CVE-2024-22428.json"
},
{
"id": "CVE-2024-38489",
"description": "Dell iDRAC Service Module version 5.3.0.0 and prior contains Out of bound write Vulnerability. A privileged local attacker could execute arbitrary code potentially resulting in a denial of service (partial) event.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-38489",
"_path": "./cvelist/2024/38xxx/CVE-2024-38489.json"
},
{
"id": "CVE-2024-38490",
"description": "Dell iDRAC Service Module version 5.3.0.0 and prior, contain a Out of bound Write Vulnerability. A privileged local attacker could execute arbitrary code potentially resulting in a denial of service event.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-38490",
"_path": "./cvelist/2024/38xxx/CVE-2024-38490.json"
},
{
"id": "CVE-2024-38481",
"description": "Dell iDRAC Service Module version 5.3.0.0 and prior, contain a Out of bound Read Vulnerability. A privileged local attacker could execute arbitrary code potentially resulting in a denial of service event.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-38481",
"_path": "./cvelist/2024/38xxx/CVE-2024-38481.json"
},
{
"id": "CVE-2024-25947",
"description": "Dell iDRAC Service Module version 5.3.0.0 and prior, contain an Out of bound Read Vulnerability. A privileged local attacker could execute arbitrary code potentially resulting in a denial of service event.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-25947",
"_path": "./cvelist/2024/25xxx/CVE-2024-25947.json"
},
{
"id": "CVE-2024-25943",
"description": "iDRAC9, versions prior to 7.00.00.172 for 14th Generation and 7.10.50.00 for 15th and 16th Generations, contains a session hijacking vulnerability in IPMI. A remote attacker could potentially exploit this vulnerability, leading to arbitrary code execution on the vulnerable application.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-25943",
"_path": "./cvelist/2024/25xxx/CVE-2024-25943.json"
},
{
"id": "CVE-2024-25948",
"description": "Dell iDRAC Service Module version 5.3.0.0 and prior, contain a Out of bound Write Vulnerability. A privileged local attacker could execute arbitrary code potentially resulting in a denial of service event.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-25948",
"_path": "./cvelist/2024/25xxx/CVE-2024-25948.json"
},
{
"id": "CVE-2013-4785",
"description": "The web interface on the Dell iDRAC6 with firmware before 1.95 allows remote attackers to modify the CLP interface for arbitrary users and possibly have other impact via a request to an unspecified form that is accessible from testurls.html. NOTE: the vendor disputes the significance of this issue, stating \"DRAC's are intended to be on a separate management network; they are not designed nor intended to be placed on or connected to the Internet.\"",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2013-4785",
"_path": "./cvelist/2013/4xxx/CVE-2013-4785.json"
},
{
"id": "CVE-2013-4783",
"description": "The Dell iDRAC6 with firmware 1.x before 1.92 and 2.x and 3.x before 3.42, and iDRAC7 with firmware before 1.23.23, allows remote attackers to bypass authentication and execute arbitrary IPMI commands by using cipher suite 0 (aka cipher zero) and an arbitrary password. NOTE: the vendor disputes the significance of this issue, stating \"DRAC's are intended to be on a separate management network; they are not designed nor intended to be placed on or connected to the Internet.\"",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2013-4783",
"_path": "./cvelist/2013/4xxx/CVE-2013-4783.json"
},
{
"id": "CVE-2013-3589",
"description": "Cross-site scripting (XSS) vulnerability in the login page in the Administrative Web Interface on Dell iDRAC6 monolithic devices with firmware before 1.96 and iDRAC7 devices with firmware before 1.46.45 allows remote attackers to inject arbitrary web script or HTML via the ErrorMsg parameter.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2013-3589",
"_path": "./cvelist/2013/3xxx/CVE-2013-3589.json"
},
{
"id": "CVE-2022-34435",
"description": "Dell iDRAC9 version 6.00.02.00 and prior contain an improper input validation vulnerability in Racadm when the firmware lock-down configuration is set. A remote high privileged attacker could exploit this vulnerability to bypass the firmware lock-down configuration and perform a firmware update.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-34435",
"_path": "./cvelist/2022/34xxx/CVE-2022-34435.json"
},
{
"id": "CVE-2022-34436",
"description": "Dell iDRAC8 version 2.83.83.83 and prior contain an improper input validation vulnerability in Racadm when the firmware lock-down configuration is set. A remote high privileged attacker could exploit this vulnerability to bypass the firmware lock-down configuration and perform a firmware update.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-34436",
"_path": "./cvelist/2022/34xxx/CVE-2022-34436.json"
},
{
"id": "CVE-2022-24422",
"description": "Dell iDRAC9 versions 5.00.00.00 and later but prior to 5.10.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to gain access to the VNC Console.",
"baseScore": 9.6,
"baseSeverity": "Critical",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-24422",
"_path": "./cvelist/2022/24xxx/CVE-2022-24422.json"
},
{
"id": "CVE-2022-24423",
"description": "Dell iDRAC8 versions prior to 2.83.83.83 contain a denial of service vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to cause resource exhaustion in the webserver, resulting in a denial of service condition.",
"baseScore": 5.3,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-24423",
"_path": "./cvelist/2022/24xxx/CVE-2022-24423.json"
},
{
"id": "CVE-2016-5685",
"description": "Dell iDRAC7 and iDRAC8 devices with firmware before 2.40.40.40 allow authenticated users to gain Bash shell access through a string injection.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2016-5685",
"_path": "./cvelist/2016/5xxx/CVE-2016-5685.json"
},
{
"id": "CVE-2014-8272",
"description": "The IPMI 1.5 functionality in Dell iDRAC6 modular before 3.65, iDRAC6 monolithic before 1.98, and iDRAC7 before 1.57.57 does not properly select session ID values, which makes it easier for remote attackers to execute arbitrary commands via a brute-force attack.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2014-8272",
"_path": "./cvelist/2014/8xxx/CVE-2014-8272.json"
},
{
"id": "CVE-2018-1212",
"description": "The web-based diagnostics console in Dell EMC iDRAC6 (Monolithic versions prior to 2.91 and Modular all versions) contains a command injection vulnerability. A remote authenticated malicious iDRAC user with access to the diagnostics console could potentially exploit this vulnerability to execute arbitrary commands as root on the affected iDRAC system.",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2018-1212",
"_path": "./cvelist/2018/1xxx/CVE-2018-1212.json"
},
{
"id": "CVE-2018-1243",
"description": "Dell EMC iDRAC6, versions prior to 2.91, iDRAC7/iDRAC8, versions prior to 2.60.60.60 and iDRAC9, versions prior to 3.21.21.21, contain a weak CGI session ID vulnerability. The sessions invoked via CGI binaries use 96-bit numeric-only session ID values, which makes it easier for remote attackers to perform bruteforce session guessing attacks.",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2018-1243",
"_path": "./cvelist/2018/1xxx/CVE-2018-1243.json"
},
{
"id": "CVE-2018-1207",
"description": "Dell EMC iDRAC7/iDRAC8, versions prior to 2.52.52.52, contain CGI injection vulnerability which could be used to execute remote code. A remote unauthenticated attacker may potentially be able to use CGI variables to execute remote code.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2018-1207",
"_path": "./cvelist/2018/1xxx/CVE-2018-1207.json"
},
{
"id": "CVE-2018-1211",
"description": "Dell EMC iDRAC7/iDRAC8, versions prior to 2.52.52.52, contain a path traversal vulnerability in its Web server's URI parser which could be used to obtain specific sensitive data without authentication. A remote unauthenticated attacker may be able to read configuration settings from the iDRAC by querying specific URI strings.",
"baseScore": "NULL",
"baseSeverity": "NULL",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2018-1211",
"_path": "./cvelist/2018/1xxx/CVE-2018-1211.json"
},
{
"id": "CVE-2018-1244",
"description": "Dell EMC iDRAC7/iDRAC8, versions prior to 2.60.60.60, and iDRAC9 versions prior to 3.21.21.21 contain a command injection vulnerability in the SNMP agent. A remote authenticated malicious iDRAC user with configuration privileges could potentially exploit this vulnerability to execute arbitrary commands on the iDRAC where SNMP alerting is enabled.",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2018-1244",
"_path": "./cvelist/2018/1xxx/CVE-2018-1244.json"
},
{
"id": "CVE-2018-1249",
"description": "Dell EMC iDRAC9 versions prior to 3.21.21.21 did not enforce the use of TLS/SSL for a connection to iDRAC web server for certain URLs. A man-in-the-middle attacker could use this vulnerability to strip the SSL/TLS protection from a connection between a client and a server.",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2018-1249",
"_path": "./cvelist/2018/1xxx/CVE-2018-1249.json"
},
{
"id": "CVE-2018-15774",
"description": "Dell EMC iDRAC7/iDRAC8 versions prior to 2.61.60.60 and iDRAC9 versions prior to 3.20.21.20, 3.21.24.22, 3.21.26.22, and 3.23.23.23 contain a privilege escalation vulnerability. An authenticated malicious iDRAC user with operator privileges could potentially exploit a permissions check flaw in the Redfish interface to gain administrator access.",
"baseScore": 3.8,
"baseSeverity": "LOW",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2018-15774",
"_path": "./cvelist/2018/15xxx/CVE-2018-15774.json"
},
{
"id": "CVE-2018-15776",
"description": "Dell EMC iDRAC7/iDRAC8 versions prior to 2.61.60.60 contain an improper error handling vulnerability. An unauthenticated attacker with physical access to the system could potentially exploit this vulnerability to get access to the u-boot shell.",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2018-15776",
"_path": "./cvelist/2018/15xxx/CVE-2018-15776.json"
},
{
"id": "CVE-2018-11053",
"description": "Dell EMC iDRAC Service Module for all supported Linux and XenServer versions v3.0.1, v3.0.2, v3.1.0, v3.2.0, when started, changes the default file permission of the hosts file of the host operating system (/etc/hosts) to world writable. A malicious low privileged operating system user or process could modify the host file and potentially redirect traffic from the intended destination to sites hosting malicious or unwanted content.",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2018-11053",
"_path": "./cvelist/2018/11xxx/CVE-2018-11053.json"
},
{
"id": "CVE-2021-21576",
"description": "Dell EMC iDRAC9 versions prior to 4.40.40.00 contain a DOM-based cross-site scripting vulnerability. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim\u2019s browser by tricking a victim in to following a specially crafted link.",
"baseScore": 6.1,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21576",
"_path": "./cvelist/2021/21xxx/CVE-2021-21576.json"
},
{
"id": "CVE-2021-21538",
"description": "Dell EMC iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to gain access to the virtual console.",
"baseScore": 9.6,
"baseSeverity": "Critical",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21538",
"_path": "./cvelist/2021/21xxx/CVE-2021-21538.json"
},
{
"id": "CVE-2021-21543",
"description": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected parameters. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application.",
"baseScore": 4.8,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21543",
"_path": "./cvelist/2021/21xxx/CVE-2021-21543.json"
},
{
"id": "CVE-2021-21579",
"description": "Dell EMC iDRAC9 versions prior to 4.40.40.00 contain an open redirect vulnerability. A remote unauthenticated attacker may exploit this vulnerability to redirect users to arbitrary web URLs by tricking the victim users to click on maliciously crafted links.",
"baseScore": 6.1,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21579",
"_path": "./cvelist/2021/21xxx/CVE-2021-21579.json"
},
{
"id": "CVE-2021-21577",
"description": "Dell EMC iDRAC9 versions prior to 4.40.40.00 contain a DOM-based cross-site scripting vulnerability. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim\u2019s browser by tricking a victim in to following a specially crafted link.",
"baseScore": 6.1,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21577",
"_path": "./cvelist/2021/21xxx/CVE-2021-21577.json"
},
{
"id": "CVE-2021-21578",
"description": "Dell EMC iDRAC9 versions prior to 4.40.40.00 contain an open redirect vulnerability. A remote unauthenticated attacker may exploit this vulnerability to redirect users to arbitrary web URLs by tricking the victim users to click on maliciously crafted links.",
"baseScore": 6.1,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21578",
"_path": "./cvelist/2021/21xxx/CVE-2021-21578.json"
},
{
"id": "CVE-2021-21544",
"description": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain an improper authentication vulnerability. A remote authenticated malicious user with high privileges could potentially exploit this vulnerability to manipulate the username field under the comment section and set the value to any user.",
"baseScore": 2.7,
"baseSeverity": "Low",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21544",
"_path": "./cvelist/2021/21xxx/CVE-2021-21544.json"
},
{
"id": "CVE-2021-21505",
"description": "Dell EMC Integrated System for Microsoft Azure Stack Hub, versions 1906 \u2013 2011, contain an undocumented default iDRAC account. A remote unauthenticated attacker, with the knowledge of the default credentials, could potentially exploit this to log in to the system to gain root privileges.",
"baseScore": 8.0,
"baseSeverity": "High",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21505",
"_path": "./cvelist/2021/21xxx/CVE-2021-21505.json"
},
{
"id": "CVE-2021-21580",
"description": "Dell EMC iDRAC8 versions prior to 2.80.80.80 & Dell EMC iDRAC9 versions prior to 5.00.00.00 contain a Content spoofing / Text injection, where a malicious URL can inject text to present a customized message on the application that can phish users into believing that the message is legitimate.",
"baseScore": 4.3,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21580",
"_path": "./cvelist/2021/21xxx/CVE-2021-21580.json"
},
{
"id": "CVE-2021-21539",
"description": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a Time-of-check Time-of-use (TOCTOU) race condition vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to gain elevated privileges when a user with higher privileges is simultaneously accessing iDRAC through the web interface.",
"baseScore": 5.9,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21539",
"_path": "./cvelist/2021/21xxx/CVE-2021-21539.json"
},
{
"id": "CVE-2021-21542",
"description": "Dell EMC iDRAC9 versions prior to 4.40.10.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected while generating a certificate. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application.",
"baseScore": 4.8,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21542",
"_path": "./cvelist/2021/21xxx/CVE-2021-21542.json"
},
{
"id": "CVE-2021-21541",
"description": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a DOM-based cross-site scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or JavaScript code to DOM environment in the browser. The malicious code is then executed by the web browser in the context of the vulnerable web application.",
"baseScore": 6.1,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21541",
"_path": "./cvelist/2021/21xxx/CVE-2021-21541.json"
},
{
"id": "CVE-2021-21581",
"description": "Dell EMC iDRAC9 versions prior to 5.00.00.00 contain a cross-site scripting vulnerability. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim\u2019s browser by tricking a victim in to following a specially crafted link.",
"baseScore": 6.5,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21581",
"_path": "./cvelist/2021/21xxx/CVE-2021-21581.json"
},
{
"id": "CVE-2021-21540",
"description": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a stack-based overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to overwrite configuration information by injecting arbitrarily large payload.",
"baseScore": 5.9,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21540",
"_path": "./cvelist/2021/21xxx/CVE-2021-21540.json"
},
{
"id": "CVE-2021-21510",
"description": "Dell iDRAC8 versions prior to 2.75.100.75 contain a host header injection vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability by injecting arbitrary \u2018Host\u2019 header values to poison a web-cache or trigger redirections.",
"baseScore": 6.1,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-21510",
"_path": "./cvelist/2021/21xxx/CVE-2021-21510.json"
},
{
"id": "CVE-2021-36346",
"description": "Dell iDRAC 8 prior to version 2.82.82.82 contain a denial of service vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability to deny access to the iDRAC webserver.",
"baseScore": 5.3,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-36346",
"_path": "./cvelist/2021/36xxx/CVE-2021-36346.json"
},
{
"id": "CVE-2021-36300",
"description": "iDRAC9 versions prior to 5.00.00.00 contain an improper input validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability by sending a specially crafted malicious request to crash the webserver or cause information disclosure.",
"baseScore": 6.5,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-36300",
"_path": "./cvelist/2021/36xxx/CVE-2021-36300.json"
},
{
"id": "CVE-2021-36299",
"description": "Dell iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.29.00 and 5.00.00.00 contain an SQL injection vulnerability. A remote authenticated malicious user with low privileges may potentially exploit this vulnerability to cause information disclosure or denial of service by supplying specially crafted input data to the affected application.",
"baseScore": 7.1,
"baseSeverity": "High",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-36299",
"_path": "./cvelist/2021/36xxx/CVE-2021-36299.json"
},
{
"id": "CVE-2021-36301",
"description": "Dell iDRAC 9 prior to version 4.40.40.00 and iDRAC 8 prior to version 2.80.80.80 contain a Stack Buffer Overflow in Racadm. An authenticated remote attacker may potentially exploit this vulnerability to control process execution and gain access to the underlying operating system.",
"baseScore": 5.9,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-36301",
"_path": "./cvelist/2021/36xxx/CVE-2021-36301.json"
},
{
"id": "CVE-2021-36347",
"description": "iDRAC9 versions prior to 5.00.20.00 and iDRAC8 versions prior to 2.82.82.82 contain a stack-based buffer overflow vulnerability. An authenticated remote attacker with high privileges could potentially exploit this vulnerability to control process execution and gain access to the iDRAC operating system.",
"baseScore": 6.2,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-36347",
"_path": "./cvelist/2021/36xxx/CVE-2021-36347.json"
},
{
"id": "CVE-2021-36348",
"description": "iDRAC9 versions prior to 5.00.20.00 contain an input injection vulnerability. A remote authenticated malicious user with low privileges may potentially exploit this vulnerability to cause information disclosure or denial of service by supplying specially crafted input data to iDRAC.",
"baseScore": 5.9,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-36348",
"_path": "./cvelist/2021/36xxx/CVE-2021-36348.json"
},
{
"id": "CVE-2019-3706",
"description": "Dell EMC iDRAC9 versions prior to 3.24.24.24, 3.21.26.22, 3.22.22.22 and 3.21.25.22 contain an authentication bypass vulnerability. A remote attacker may potentially exploit this vulnerability to bypass authentication and gain access to the system by sending specially crafted data to the iDRAC web interface.",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2019-3706",
"_path": "./cvelist/2019/3xxx/CVE-2019-3706.json"
},
{
"id": "CVE-2019-3707",
"description": "Dell EMC iDRAC9 versions prior to 3.30.30.30 contain an authentication bypass vulnerability. A remote attacker may potentially exploit this vulnerability to bypass authentication and gain access to the system by sending specially crafted input data to the WS-MAN interface.",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2019-3707",
"_path": "./cvelist/2019/3xxx/CVE-2019-3707.json"
},
{
"id": "CVE-2019-3764",
"description": "Dell EMC iDRAC7 versions prior to 2.65.65.65, iDRAC8 versions prior to 2.70.70.70 and iDRAC9 versions prior to 3.36.36.36 contain an improper authorization vulnerability. A remote authenticated malicious iDRAC user with low privileges may potentially exploit this vulnerability to obtain sensitive information such as password hashes.",
"baseScore": 5.0,
"baseSeverity": "Medium",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2019-3764",
"_path": "./cvelist/2019/3xxx/CVE-2019-3764.json"
},
{
"id": "CVE-2019-3705",
"description": "Dell EMC iDRAC6 versions prior to 2.92, iDRAC7/iDRAC8 versions prior to 2.61.60.60, and iDRAC9 versions prior to 3.20.21.20, 3.21.24.22, 3.21.26.22 and 3.23.23.23 contain a stack-based buffer overflow vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to crash the webserver or execute arbitrary code on the system with privileges of the webserver by sending specially crafted input data to the affected system.",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2019-3705",
"_path": "./cvelist/2019/3xxx/CVE-2019-3705.json"
}
]