forked from SamCoppen/NBFCProfile
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathHP EliteBook x360 1030 G3.xml
72 lines (72 loc) · 2.79 KB
/
HP EliteBook x360 1030 G3.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
<?xml version="1.0"?>
<FanControlConfigV2 xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<NotebookModel>HP EliteBook X360 1030 G3</NotebookModel>
<Author>Sam Coppen</Author>
<EcPollInterval>500</EcPollInterval>
<ReadWriteWords>false</ReadWriteWords>
<CriticalTemperature>95</CriticalTemperature>
<FanConfigurations>
<FanConfiguration>
<ReadRegister>46</ReadRegister>
<WriteRegister>47</WriteRegister>
<MinSpeedValue>254</MinSpeedValue>
<MaxSpeedValue>26</MaxSpeedValue>
<IndependentReadMinMaxValues>false</IndependentReadMinMaxValues>
<MinSpeedValueRead>0</MinSpeedValueRead>
<MaxSpeedValueRead>0</MaxSpeedValueRead>
<ResetRequired>true</ResetRequired>
<FanSpeedResetValue>255</FanSpeedResetValue>
<FanDisplayName>CPU Fan</FanDisplayName>
<TemperatureThresholds>
<TemperatureThreshold>
<UpThreshold>0</UpThreshold>
<DownThreshold>0</DownThreshold>
<FanSpeed>0</FanSpeed>
</TemperatureThreshold>
<TemperatureThreshold>
<UpThreshold>60</UpThreshold>
<DownThreshold>55</DownThreshold>
<FanSpeed>10.08772</FanSpeed>
</TemperatureThreshold>
<TemperatureThreshold>
<UpThreshold>70</UpThreshold>
<DownThreshold>65</DownThreshold>
<FanSpeed>20.17544</FanSpeed>
</TemperatureThreshold>
<TemperatureThreshold>
<UpThreshold>80</UpThreshold>
<DownThreshold>75</DownThreshold>
<FanSpeed>30.2631588</FanSpeed>
</TemperatureThreshold>
<TemperatureThreshold>
<UpThreshold>95</UpThreshold>
<DownThreshold>85</DownThreshold>
<FanSpeed>100</FanSpeed>
</TemperatureThreshold>
</TemperatureThresholds>
<FanSpeedPercentageOverrides />
</FanConfiguration>
</FanConfigurations>
<RegisterWriteConfigurations>
<RegisterWriteConfiguration>
<WriteMode>Set</WriteMode>
<WriteOccasion>OnInitialization</WriteOccasion>
<Register>35</Register>
<Value>1</Value>
<ResetRequired>true</ResetRequired>
<ResetValue>1</ResetValue>
<ResetWriteMode>Set</ResetWriteMode>
<Description>Select thermal zone</Description>
</RegisterWriteConfiguration>
<RegisterWriteConfiguration>
<WriteMode>Set</WriteMode>
<WriteOccasion>OnInitialization</WriteOccasion>
<Register>39</Register>
<Value>28</Value>
<ResetRequired>true</ResetRequired>
<ResetValue>0</ResetValue>
<ResetWriteMode>Set</ResetWriteMode>
<Description>Fake thermal zone temperature</Description>
</RegisterWriteConfiguration>
</RegisterWriteConfigurations>
</FanControlConfigV2>