#python script for reading analog values from A2D DAQ
from lab_equipment import A2D_DAQ_control as AD_control
import pandas as pd
import time
import easygui as eg
import FileIO
pull_up_v = 3.3
pull_up_r = 3300
pull_up_cal_ch = 63
def gather_and_write_data(filepath, time, print_all=False, print_max = True):
daq.set_led(1)
#recalibrate pullup voltage
daq.calibrate_pullup_v(pull_up_cal_ch)
pull_up_v = daq.pullup_voltage
data = {}
#add timestamp
data["Timestamp"] = time
max_temp_c = -273.15
max_temp_c_groups = [-273.15, -273.15, -273.15, -273.15]
#read all analog values
for ch in range(daq.num_channels):
volts = daq.measure_voltage(ch)
data["Channel_{}".format(ch)] = volts*1000.0
if(volts > pull_up_v):
volts = pull_up_v
temp_c = daq.measure_temperature(ch)
if(ch/16 < 1):
if(temp_c > max_temp_c_groups[0]):
max_temp_c_groups[0] = temp_c
elif(ch/32 < 1):
if(temp_c > max_temp_c_groups[1]):
max_temp_c_groups[1] = temp_c
elif(ch/48 < 1):
if(temp_c > max_temp_c_groups[2]):
max_temp_c_groups[2] = temp_c
else:
if(temp_c > max_temp_c_groups[3]):
max_temp_c_groups[3] = temp_c
data["Channel_C_{}".format(ch)] = temp_c
if(print_all):
print(data)
if(print_max):
print('Max Temps (C)\tCH0-15: {:.1f}'.format(max_temp_c_groups[0]) +
'\tCH16-31: {:.1f}'.format(max_temp_c_groups[1]) +
'\tCH32-47: {:.1f}'.format(max_temp_c_groups[2]) +
'\tCH48-63: {:.1f}'.format(max_temp_c_groups[3]))
FileIO.write_line(filepath, data)
daq.set_led(0)
######################### Program ########################
if __name__ == '__main__':
#declare and initialize the daq
daq = AD_control.A2D_DAQ()
#Gather the test settings
lb = 1
ub = 60
msg = 'Enter logging interval in seconds (from {} to {}):'.format(lb, ub)
title = 'Logging Interval'
interval_temp = eg.integerbox(msg, title, default = 5, lowerbound = lb, upperbound = ub)
dir = FileIO.get_directory()
path = FileIO.start_file(dir, 'A2D-DAQ-Results')
#read all analog channels once every X seconds
starttime = time.time()
while True:
try:
gather_and_write_data(path, time=time.time())
time.sleep(interval_temp - ((time.time() - starttime) % interval_temp))
except KeyboardInterrupt:
#make sure all outputs are off before quiting
daq.reset()
exit()