Notifications
You must be signed in to change notification settings - Fork 36
/
Copy pathmytestsuite.py
223 lines (189 loc) · 11 KB
/
mytestsuite.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
# For testing.
#
# Concept: This module allows to trigger abnormal situations, to test the reaction of the software ("fault insertion testing").
# In the place in the software, where the fault shall be injected, add a condition like
# if (testsuite_faultinjection_is_triggered(TC_MY_TESTCASE_FOR_SOMETHING)):
# DoSomethingStrange()
# In normal software run, this condition is never fulfilled and does not disturb. If the related test case is activated,
# by setting testsuite_testcase_number = TC_MY_TESTCASE_FOR_SOMETHING below, the condition will fire and the fault is injected.
# A number of delay cycles can be configured with testsuite_delayCycles below.
#
# Detailled docu see doc/testing_and_simulation.md
from udplog import udplog_log
from configmodule import getConfigValue, getConfigValueBool
# The list of test cases. Each must have a unique test case ID.
TC_NOTHING_TO_TEST = 0
TC_EVSE_ResponseCode_SequenceError_for_SessionSetup = 1
TC_EVSE_ResponseCode_Failed_for_CableCheckRes = 2
TC_EVSE_ResponseCode_SequenceError_for_ServiceDiscoveryRes = 3
TC_EVSE_ResponseCode_SequenceError_for_ServicePaymentSelectionRes = 4
TC_EVSE_ResponseCode_SequenceError_for_ContractAuthenticationRes = 5
TC_EVSE_ResponseCode_ServiceSelectionInvalid_for_ChargeParameterDiscovery = 6
TC_EVSE_ResponseCode_Failed_for_PreChargeRes = 7
TC_EVSE_ResponseCode_Failed_for_PowerDeliveryRes = 8
TC_EVSE_ResponseCode_Failed_for_CurrentDemandRes = 9
TC_EVSE_Timeout_during_CableCheck = 10
TC_EVSE_Timeout_during_PreCharge = 11
TC_EVSE_Shutdown_during_PreCharge = 12
TC_EVSE_Shutdown_during_CurrentDemand = 13
TC_EVSE_Malfunction_during_CurrentDemand = 14
TC_EVSE_Timeout_during_CurrentDemand = 15
TC_EVSE_GoodCase = 16
TC_EVSE_LastTest = 17
# variables
testsuite_testcase_number = 0
testsuite_delayCycles = 0
testsuite_TcTitle = "(title not initialized)"
# Counter variable for delaying the trigger
testsuite_counter = 0
def testsuite_printToTestLog(s):
fileOut = open('testresults.txt', 'a') # open the result file for appending
print(s, file=fileOut)
fileOut.close()
def testsuite_getTcNumber():
if (testsuite_testcase_number==0):
return "(no tests)"
else:
return str(testsuite_testcase_number) + testsuite_TcTitle
def testsuite_faultinjection_is_triggered(context):
global testsuite_counter, testsuite_testcase_number, testsuite_delayCycles
isTestcaseFired = False
if (context==testsuite_testcase_number): # if the call context is matching the intended test case
testsuite_counter += 1 # count the number of matching calls
isTestcaseFired = testsuite_counter>=testsuite_delayCycles # and fire the test case if the intended number is reached
if (isTestcaseFired):
print("[TESTSUITE] Fired test case " + str(context) + " TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT")
s = "[TESTSUITE] Fired test case " + str(context)
udplog_log(s, "testsuite")
return isTestcaseFired
def testsuite_choose_testcase():
global testsuite_counter, testsuite_testcase_number, testsuite_delayCycles
global testsuite_observedResult
global testsuite_expectedResult
global testsuite_TcTitle
if (not getConfigValueBool("testsuite_enable")):
testsuite_testcase_number = TC_NOTHING_TO_TEST
return
try:
if (testsuite_expectedResult is None):
testsuite_expectedResult = ""
except:
testsuite_expectedResult = ""
# as first step, before choosing the next test case, check the result of the ongoing test case
if (testsuite_expectedResult!=""):
s = "ExpectedResult: " + testsuite_expectedResult
s = s + ", ObservedResult: " + testsuite_observedResult
if (testsuite_expectedResult!=testsuite_observedResult):
s = "FAIL " + s
else:
s = "PASS " + s
print(s)
udplog_log(s, "testsuite")
x = "Result for Testcase " + str(testsuite_testcase_number) + " " + testsuite_TcTitle
testsuite_printToTestLog(x)
testsuite_printToTestLog(s)
if (testsuite_testcase_number<TC_EVSE_LastTest):
testsuite_testcase_number+=1
print("[TESTSUITE] Setting up test case " + str(testsuite_testcase_number) + " TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT")
s = "[TESTSUITE] Setting up test case " + str(testsuite_testcase_number)
udplog_log(s, "testsuite")
testsuite_counter = 0
testsuite_delayCycles = 5 # just a default
testsuite_expectedResult = "" # just a default
testsuite_observedResult = "" # just a default
testsuite_TcTitle = "(title missing)" # just a default
# For each test case, configure the test parameters and the expected result
if (testsuite_testcase_number == TC_EVSE_Timeout_during_CableCheck):
testsuite_delayCycles=0 # immediately timeout
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "Timeout during CableCheck shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_Timeout_during_PreCharge):
testsuite_delayCycles=0 # immediately timeout
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "Timeout during PreCharge shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_Shutdown_during_PreCharge):
testsuite_delayCycles=2 # shutdown after 2 ok-cycles
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "Shutdown during PreCharge shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_Shutdown_during_CurrentDemand):
testsuite_delayCycles=20 # shutdown after 20 ok-cycles
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "Shutdown during CurrentDemand shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_Malfunction_during_CurrentDemand):
testsuite_delayCycles=5 # malfunction after 5 ok-cycles
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "Malfunction during CurrentDemand shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_Timeout_during_CurrentDemand):
testsuite_delayCycles=30 # timeout after 30 ok-cycles
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "Timeout during CurrentDemand shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_ResponseCode_SequenceError_for_SessionSetup):
testsuite_delayCycles=0 # immediately
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "SequenceError in SessionSetup shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_ResponseCode_SequenceError_for_ServiceDiscoveryRes):
testsuite_delayCycles=0 # immediately
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "SequenceError in ServiceDiscoveryRes shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_ResponseCode_SequenceError_for_ServicePaymentSelectionRes):
testsuite_delayCycles=0 # immediately
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "SequenceError in ServicePaymentSelectionRes shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_ResponseCode_SequenceError_for_ContractAuthenticationRes):
testsuite_delayCycles=0 # immediately
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "SequenceError in ContractAuthenticationRes shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_ResponseCode_ServiceSelectionInvalid_for_ChargeParameterDiscovery):
testsuite_delayCycles=0 # immediately
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "ServiceSelectionInvalid in ChargeParameterDiscoveryshall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_ResponseCode_Failed_for_CableCheckRes):
testsuite_delayCycles=0 # immediately in the first message
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "Failed in CableCheckRes shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_ResponseCode_Failed_for_PreChargeRes):
testsuite_delayCycles=2 # after two ok cycles, we inject the fault in the third cycle
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "Failed in PreChargeRes shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_ResponseCode_Failed_for_PowerDeliveryRes):
testsuite_delayCycles=0 # immediately
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "Failed in PowerDeliveryRes shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_ResponseCode_Failed_for_CurrentDemandRes):
testsuite_delayCycles=10 # fire the fault after 10 ok-cycles
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
testsuite_TcTitle = "Failed in CurrentDemandRes shall lead to SafeShutdown"
if (testsuite_testcase_number == TC_EVSE_GoodCase):
# Test case for the good case: Normal charging, no errors.
testsuite_delayCycles=0 # not relevant
testsuite_expectedResult = "TSRS_ChargingFinished"
testsuite_TcTitle = "Good case, normal charging without errors"
def testsuite_reportstatus(s):
# give the test status to the UDP, to inform the other side and to have it in the network log.
udplog_log(s, "testsuite")
pass
def testsuite_evaluateIpv4Packet(pkt):
# The testsuite listens to syslog messages which are coming from the other side,
# to know what is going on.
global testsuite_observedResult
if (len(pkt)>50):
protocol = pkt[23]
destinationport = pkt[36]*256 + pkt[37]
if ((protocol == 0x11) and (destinationport==0x0202)): # it is an UDP packet to the syslog port
baSyslog = pkt[46:]
strSyslog = ""
syslogLen = len(baSyslog)
if (syslogLen>100):
syslogLen=100
for i in range(0, syslogLen-1): # one less, remove the trailing 0x00
x = baSyslog[i]
if (x<0x20):
x=0x20 # make unprintable character to space.
strSyslog+=chr(x) # convert ASCII code to string
print("[Testsuite] received syslog packet: " + strSyslog)
if (strSyslog[0:5]=="TSRS_"):
# it is a TestSuiteReportStatus message.
testsuite_observedResult = strSyslog
if __name__ == "__main__":
print("Testing the mytestsuite")
print("nothing to do")