Notifications
You must be signed in to change notification settings - Fork 197
MQTT Features
Sonoff responds to the following MQTT commands using MQTT Topic for cmnd/sonoff/<command>
and MQTT Message/Payload for <parameter>
:
-
the relay can be controlled with
cmnd/sonoff/power on
,cmnd/sonoff/power off
orcmnd/sonoff/power toggle
. The LED will blink twice and sends a MQTT status message likestat/sonoff/POWER ON
. The same function can be initiated withcmnd/sonoff/light on
. -
starting with version 3.0.0 the power state message can be sent with the retain flag set. Enable this with
cmnd/sonoff/PowerRetain on
. -
starting with version 3.0.0 for sonoff dual the relays need to be addressed with
cmnd/sonoff/power1 toggle
andcmnd/sonoff/power2 toggle
. From version 2.0.0 until version 3.0.0 the relays could be addressed withcmnd/sonoff/1/power toggle
andcmnd/sonoff/2/power toggle
. -
the MQTT topic can be changed with
cmnd/sonoff/topic sonoff1
which reboots sonoff and makes it available for MQTT commands likecmnd/sonoff1/power on
. -
the OTA firmware location can be made known to sonoff with
cmnd/sonoff/otaurl http://domus1:80/api/sonoff/user1.bin
where domus1 is your webserver hosting the firmware. Reset to default withcmnd/sonoff/otaurl 1
. -
upgrade OTA firmware with
cmnd/sonoff/upgrade 1
. -
show all status information with
cmnd/sonoff/status 0
. -
The button can send a MQTT message to the broker that in turn will switch the relay. To configure this you need to perform
cmnd/sonoff/ButtonTopic sonoff
where sonoff equals to Topic. The message can also be provided with the retain flag bycmnd/sonoff/ButtonRetain on
. -
Sonoff Pow status can be retreived with
cmnd/sonoff/status 8
or periodically every 5 minutes usingcmnd/sonoff/TelePeriod 300
. If units appended to the message are needed execute commandcmnd/sonoff/MqttUnits on
. -
When a Sonoff Pow threshold like PowerLow has been met a message
tele/sonoff/POWER_LOW ON
will be sent. When the error is corrected a messagetele/sonoff/POWER_LOW OFF
will be sent.
Most MQTT commands will result in a status feedback like stat/sonoff/POWER ON
and/or {"POWER":"ON"} depending of cmnd/sonoff/MessageFormat Legacy|JSON
. The power state will ALWAYS be returned in Legacy mode (for easy triggering by home automation tool) and optionally in JSON.
Telemetry data will be sent by prefix tele
like tele/sonoff/TEMPERATURE 24.7