v2.1.0 release
This release adds the following features:
- Sungrow SH-##-RT/RS inverters are now marked as stable ✅ 🥳
- BYD CAN now stops transmitting CAN messages incase BMS raises a fault. This is done to signal to the inverter that charging/discharging needs to stop. CAN mapping scaling for BYD CAN also adjusted after user testing
- The supported inverter list has been expanded with more inverters that most likely work with the code
- Automatic contactor closing via LilyGo now implemented ✅ Added a wiki section on how to use this feature with LEAF batteries
- Basic Chademo support added
- Updated images on how to power the LilyGo board. Recommended way now is via USB port, the external 5-12V connector can cause the board to crash. So USB will be the only recommendation from now on!
- The LED on the board now lights up blue 🔵 , incase CAN wiring is incorrect on startup. Possible causes are swapped High/Low pair, wire disconnected, or wrong terminating resistance. Check CAN wiring if you see this blue LED!