Expand Up @@ -9,7 +9,9 @@ import Link from '@docusaurus/Link'

The `/api/v1/data` endpoint allows you to get the most recent measurement from the device. All data points are "optional"; The API does not send data points that are `null` or not available at all. This mostly depends on the connected smart meter. Make sure your application can handle this.

## Data points for **HWE-P1**
## P1 Meter (HWE-P1)

### Data points

| Data | Type | Description |
| --------------------------- | ------ | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
Expand Down Expand Up @@ -55,7 +57,7 @@ The `/api/v1/data` endpoint allows you to get the most recent measurement from t
| unique_gas_id | Number | The unique identifier for the gas meter, can be used to migrate to the 'external' data point |
| external | Array | A list of externally connected utility meters, see [External data point](#external-data-point) for more information |

## `External` data point
### `External` data point

Some smart meters have more than one external device connected to it. This can be, for example, a gas and a water meter. The `external` data point adds support for these devices.
Each entry is supplied with a set of data. See [this example](#hwe-p1-3-phase-with-gas).
Expand All @@ -70,11 +72,11 @@ Each entry is supplied with a set of data. See [this example](#hwe-p1-3-phase-wi

The original data points `total_gas_m3`, `gas_timestamp` and `unique_gas_id` use the first detected gas meter. These data points will be removed in a future version. You can use `unique_id` to migrate any values if needed.

## Monthly power peak
### Monthly power peak

Belgium users are started to get charged for the peak usage per month (see <Link to="https://www.fluvius.be/nl/thema/factuur-en-tarieven/capaciteitstarief">capaciteitstarief</Link>). The data points `active_power_average_w`, `montly_power_peak_w` and `montly_power_peak_timestamp` can be used to track the maximum demand.

## HWE-P1 (1-phase, no gas)
### Example: HWE-P1 (1-phase, no gas)

```
<Request>
Expand All @@ -99,7 +101,7 @@ Content-Length: <length>
}
```

### HWE-P1 (3-phase, with gas and water meter)
### Example: HWE-P1 (3-phase, with gas and water meter)

```
<Request>
Expand Down Expand Up @@ -188,7 +190,7 @@ The firmware version 4.00 is currently in beta and is tested by a small group of
| active_power_factor | Number | HWE-SKT-21 | The power factor | 4.07 or later |
| active_frequency_hz | Number | All | The frequency in hertz | 4.07 or later |

### Example (HWE-SKT-11)
### Example: HWE-SKT-11

```
<Request>
Expand All @@ -214,7 +216,7 @@ Content-Length: <length>
}
```

### Example (HWE-SKT-21)
### Example: HWE-SKT-21

```
<Request>
Expand Down
6 changes: 3 additions & 3 deletions docs/endpoints/api-v1-identify.mdx
Original file line number Diff line number Diff line change
Expand Up @@ -9,9 +9,9 @@ The `/api/v1/identify` endpoint can be used to let the user identify the device.

This feature is available for:

- HWE-P1
- HWE-SKT
- HWE-WTR (firmware version 3.00 or later required)
- P1 Meter (HWE-P1)
- Energy Socket (HWE-SKT)
- Watermeter (HWE-WTR) (firmware version 3.00 or later required)

:::info Watermeter support
Support for this endpoint in the Watermeter will be added in version 3.00. This version is currently in beta and is tested by a small group of users. The firmware will be released to all users when the beta phase is completed.
Expand Down
2 changes: 1 addition & 1 deletion docs/endpoints/api-v1-state.mdx
Original file line number Diff line number Diff line change
Expand Up @@ -5,7 +5,7 @@ description: Control the state of the Energy Socket.

# Control socket state (`/api/v1/state`)

The `/api/v1/state` endpoint returns the actual state of the Energy Socket. This endpoint is only available for the Energy Socket as this is the only controllable device.
The `/api/v1/state` endpoint returns the actual state of the Energy Socket. This endpoint is **only available for the Energy Socket (HWE-SKT)** as this is the only controllable device.

This endpoint accepts `GET` and `PUT` requests.

Expand Down
10 changes: 5 additions & 5 deletions docs/endpoints/api-v1-system.mdx
Original file line number Diff line number Diff line change
Expand Up @@ -9,11 +9,11 @@ The `/api/v1/system` endpoint can be used to configure system settings. Currentl

This feature is currently only available for:

- HWE-P1
- HWE-SKT
- HWE-KWH1 / SDM230-wifi
- HWE-KWH3 / SDM630-wifi
- HWE-WTR (firmware version 3.00 or later required)
- P1 Meter (HWE-P1)
- Energy Socket (HWE-SKT)
- kWh Meter 1-phase (HWE-KWH1 / SDM230-wifi)
- kWh Meter (HWE-KWH3 / SDM630-wifi)
- Watermeter (HWE-WTR) (firmware version 3.00 or later required)

:::info Watermeter support
Support for this endpoint in the Watermeter will be added in version 3.00. This version is currently in beta and is tested by a small group of users. The firmware will be released to all users when the beta phase is completed.
Expand Down
2 changes: 1 addition & 1 deletion docs/endpoints/api-v1-telegram.mdx
Original file line number Diff line number Diff line change
Expand Up @@ -5,7 +5,7 @@ description: Get the most recent, raw telegram from the P1 meter.

# P1 telegram (`/api/v1/telegram`)

The `/api/v1/telegram` endpoint returns the most recent, valid telegram that was given by the P1 meter, therefore this endpoint is **only available for the HWE-P1**.
The `/api/v1/telegram` endpoint returns the most recent, valid telegram that was given by the P1 meter, therefore this endpoint is **only available for the P1 Meter (HWE-P1)**.

- The telegram validated with its CRC, but not parsed in any form.
- Note that this endpoint returns plain text instead of formatted JSON, even when an error occurs (see [Error handling](/docs/error-handling))
Expand Down