# 2024-12-11 Firmware upgrade on off2 | ||
|
||
We noticed that on off2, the latency was really high for two of the hard drives, | ||
namely sdc and sdd. | ||
|
||
After some research, Christian found that it could be linked to an old firmware on the disks. | ||
|
||
## Preparation | ||
|
||
We can see firmware version by using (here for sdd): | ||
```bash | ||
smartctl -a /dev/sdd|grep -i firmware | ||
``` | ||
It was `GB01` on the two culprits, while it was `GB03` on the others. | ||
|
||
Christian downloaded the firmware update for the disks, | ||
it comes as an installer: `Serial-ATA_Firmware_0942Y_LN_GB03_A00.BIN` | ||
|
||
You can find it by using the "Device Model" entry from `smartctl -a` (here `TOSHIBA MG07ACA14TEY`) | ||
and search for firmwaon the flyre. You land on `https://www.dell.com/support/home/fr-fr/drivers/driversdetails?driverid=0942y` | ||
|
||
|
||
## Changing the firmware | ||
|
||
The firmware update is happening on all disk on the server. | ||
|
||
We just run the program as root and it went smoothly. | ||
|
||
But we wanted to be sure that the firmware upgrade was taken into account | ||
(we didn't have the time to wait for a check, | ||
and where not sure of the figure seen with `zpool iostat`). | ||
|
||
So we decided to remove and re-add the disks to the server. | ||
Because our ZFS is raidz we can remove one disk at a time without losing data, | ||
and because we will remove it only for a short period, re-silver will be fast. | ||
|
||
So we removed sdd from ZFS pools | ||
```bash | ||
zpool offline zfs-hdd sdd4 | ||
# for rpool the name is different, but we can recognize thanks to the serial number (smartctl -a gives it) | ||
zpool offline rpool ata-TOSHIBA_MG07ACA14TEY_X8F0A0H8F9RG-part3 | ||
``` | ||
|
||
We unplugged the disk and plugged it back in. | ||
|
||
Then we re-added it to the ZFS pools: | ||
```bash | ||
zpool online zfs-hdd sdd4 | ||
zpool online rpool ata-TOSHIBA_MG07ACA14TEY_X8F0A0H8F9RG-part3 | ||
``` | ||
|
||
We then wait for re-silver to be completed, zpool status displays if a resilver is in progress or done: | ||
```bash | ||
zpool status | ||
``` | ||
It was almost instantaneous. | ||
|
||
We did the same operation for the other disk, `sdc`. | ||
|
||
Note: we did not offlined the disk from rpool because we forgot to do it. It went well the same, | ||
because ZFS was resilient enough and did the resilver automatically. | ||
|
||
|
||
## Result | ||
|
||
The result is easy to see in munin: | ||
|
||
![disk latency graph](./media/2024-12-11-munin-off2-latency-after-firmware-update.png) | ||
|
||
![disk usage graph](./media/2024-12-11-munin-off2-usage-after-firmware-update.png) |
Binary file added
BIN
+77.1 KB
docs/reports/media/2024-12-11-munin-off2-latency-after-firmware-update.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added
BIN
+61.3 KB
docs/reports/media/2024-12-11-munin-off2-usage-after-firmware-update.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.