Skip to content

Commit

Permalink
Merge pull request #42 from bhawnasehgal/main
Browse files Browse the repository at this point in the history
Update content for skin prep guide, patchy, shield, & BioAmp EXG Pill
  • Loading branch information
lorforlinux authored May 16, 2024
2 parents 9f0d78f + c65c3ce commit 91a1877
Show file tree
Hide file tree
Showing 19 changed files with 94 additions and 44 deletions.
102 changes: 76 additions & 26 deletions guides/usage-guides/skin-preparation/index.rst
Original file line number Diff line number Diff line change
Expand Up @@ -8,26 +8,35 @@ Why skin preparation is important?

Proper skin preparation is crucial before recording any biopotential signal be it Electrocardiography (ECG), Electromyography (EMG), Electroencephalography (EEG), or Electrooculography (EOG).

- ``Clear recording surface`` Removes dead skin cells, oils, & other substances that increases skin impedance.
- ``Clean skin surface`` Removes dead skin cells, oils, & other substances that increases skin impedance.
- ``Improve impedance`` Improves the conduction of electrical signals from the body to the recording equipment and minimizes impedance.
- ``Electrode-skin contact`` Ensures optimal contact between the electrodes and the skin surface.
- ``Signal quality`` Enhances the overall quality of recorded signals, providing clear & reliable data for analysis & improves the ability to capture subtle variations in biopotential signals.
- ``Consistency in recordings`` Reduces variability in signal quality, making it easier to make any Human-Computer Interface (HCI), Brain-Computer Interface (BCI) project or a real-world application.
- ``Long term adhesion`` Facilitates long-term adhesion & stable placement of electrodes to the skin during extended signal monitoring.

Requirements
Kit Contents
**************

.. _Nuprep gel: https://store.upsidedownlabs.tech/product/nuprep-gel/
.. _Electrode gel: https://store.upsidedownlabs.tech/product/electrode-gel/
.. _Ten20 paste: https://store.upsidedownlabs.tech/product/ten20-paste/

+-------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| `Nuprep gel`_ | Mildly abrasive, highly conductive gel that should be applied before placing the electrodes on the skin to improve signal quality & enhances the performance of monitoring electrodes. |
+-------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| **NuPrep Gel** | Mildly abrasive, highly conductive gel that should be applied before placing the electrodes on the skin to improve signal quality & enhances the performance of monitoring electrodes. |
| `Electrode Gel`_ | Highly conductive gel that acts as a coupling agent between dry electrodes and the skin to aid the transmission of biopotential signals like ECG, EMG, EOG, or EEG. |
+-------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| **Electrode Gel** | Highly conductive gel that acts as a coupling agent between electrodes and the skin to aid the transmission of biopotential signals like ECG, EMG, EOG, or EEG. |
| `Ten20 paste`_ | Contains the right balance of adhesiveness and conductivity, enabling the dry electrodes to remain in place while allowing the transmittance of biopotential signals. |
+-------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| **Ten20 Paste** | Contains the right balance of adhesiveness and conductivity, enabling the dry electrodes to remain in place while allowing the transmittance of biopotential signals. |
| Alcohol Swabs/Wet wipes | Soft & non-woven pads that helps in cleaning the skin surface and does not leave any residue. |
+-------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| **Alcohol Swabs/Wet wipes** | Soft & non-woven pads that helps in cleaning the skin surface and does not leave any residue. |
| Cotton Swabs | Useful while applying nuprep gel or ten20 paste. |
+-------------------------------------+-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+

.. figure:: media/kit-contents.*
:align: center

Steps to follow
*****************

Expand All @@ -36,52 +45,93 @@ You can follow the steps given below to do the skin preparation properly:
Step 1: Identify the targeted area
=====================================

Identify the target area where the gel electrodes will be placed for recording ECG, EMG, EEG, or EOG.
Identify the target area where the gel electrodes or BioAmp Bands will be placed for recording the biopotential signals.

.. figure:: media/skin-prep-eog.*
:align: center

Target area to record EOG

.. image:: media/skin-prep-eog.*
.. figure:: media/skin-prep-emg.*
:align: center

.. image:: media/skin-prep-emg.*
Target area to record EMG

.. image:: media/skin-prep-ecg.*
.. figure:: media/skin-prep-ecg.*
:align: center

.. image:: media/skin-prep-eeg.*
Target area to record ECG

Step 2: Apply the gel
======================
.. figure:: media/skin-prep-eeg.*
:align: center

Apply a drop of NuPrep gel to your targeted area where the electrodes will be placed.
Target area to record EEG

.. image:: media/step-2.*
Step 2: Apply NuPrep gel
==========================

Step 3
=======
Take a small amount of NuPrep gel using a cotton swab and apply it on your targeted area.

.. figure:: media/step-2.*

Step 3: Clean the skin surface
===============================

Use gentle, circular motions to rub the gel on the skin surface. This removes all the dead skin cells & improves conductivity.

.. figure:: media/step-3.*
:align: center

Rub the gel gently using the cotton swab

.. warning:: Do not rub the gel for too long as it has abrasive properties and may cause skin redness and irritation.

Step 4
========
Step 4: Wipe off the gel
===================================

Wipe away excess gel with alcohol swabs or wet wipes.

Wipe away excess gel with the alcohol swabs or wet wipes.
.. figure:: media/step-4.*
:align: center

Wipe away access gel

.. warning:: Close your eyes while using the alcohol swabs for EOG recording else it may cause eye redness & irritation.

Step 5
========
Step 5: Measuring the signals
=================================

Now you can either use gel electrodes or the BioAmp bands for the signal recording.
Now you can either use gel electrodes or BioAmp bands for the signal recording.

Using gel electrodes
----------------------

Connect the BioAmp cable to gel electrodes, peel the plastic backing from electrodes and place the IN+, IN-, REF cables according to your specific biopotential recording.
Connect the BioAmp cable to gel electrodes, peel the plastic backing from electrodes and place the IN+, IN-, REF cables according to your specific biopotential recording.

.. figure:: media/step-5a.*
:align: center

Placing gel electrodes on skin surface

.. note:: While placing the gel electrodes on the skin, make sure to place the non-sticky tab of the electrode in the direction opposite to your hair growth. This allows you to remove the electrodes easily without pulling off much body hair.

Using BioAmp bands
----------------------

Connect the BioAmp cable to your BioAmp band. Now apply a small amount of electrode gel or Ten20 conductive paste on the dry electrodes between the skin and metallic part of BioAmp cable. This improves the signal conductivity, enhancing overall signal quality.
Connect the BioAmp cable to your BioAmp band. Now apply a small amount of ``electrode gel`` or ``Ten20 conductive paste`` on the dry electrodes between the skin and metallic part of BioAmp cable. This improves the signal conductivity, enhancing overall signal quality.

.. figure:: media/step-5b.*
:align: center

Method 1: Using Electrode gel

.. figure:: media/step-5c.*
:align: center

Method 2: Using Ten20 paste

.. note:: The above graphics demonstrates the use of electrode gel/Ten20 paste with Muscle BioAmp Band. Similarly you can use Brain BioAmp Band and Heart BioAmp Band. Refer to :ref:`using-bioamp-bands` guide to assemble and use all the BioAmp Bands correctly.

Now you are all set! Make all the connections correctly and start recording your biopotential signals.

.. note:: NuPrep gel, Ten20 paste and the alcohol swabs shouldn't be used if you have a history of skin allergies to lotions and cosmetics.
.. warning:: NuPrep gel, Ten20 paste and the alcohol swabs shouldn't be used if you have a history of skin allergies to lotions and cosmetics.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file modified guides/usage-guides/skin-preparation/media/step-2.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
2 changes: 2 additions & 0 deletions hardware/bioamp/bioamp-exg-pill/index.rst
Original file line number Diff line number Diff line change
Expand Up @@ -3,6 +3,8 @@
BioAmp EXG Pill
##################

:bdg-danger:`v1.0`

Overview
*********

Expand Down
32 changes: 15 additions & 17 deletions hardware/bioamp/muscle-bioamp-patchy/index.rst
Original file line number Diff line number Diff line change
Expand Up @@ -47,36 +47,32 @@ Hardware

Images below shows a quick overview of the hardware design.

.. grid:: 1 1 2 2
:margin: 4 4 0 0
:gutter: 2

.. grid-item::
.. card::
.. figure:: media/PCB-Front.*
:align: center
:width: 60%

**PCB Front**
^^^^^
.. figure:: media/PCB-Front.*
PCB Front

.. grid-item::
.. card::
.. figure:: media/PCB-Back.*
:align: center
:width: 60%

**PCB Back**
^^^^^
.. figure:: media/PCB-Back.*
PCB Back

.. figure:: media/Muscle-BioAmp-Patchy-Assembled-Front.*
:align: center
:width: 60%

.. figure:: media/Muscle-BioAmp-Patchy-Assembled-Back.*
:align: center
Assembled PCB

Contents of the kit
********************

.. image:: media/kit-contents.*

We have made a complete unboxing video of the kit. Please find the link below:

.. youtube:: qRKU_HvapDE
:align: center
:width: 100%
Expand Down Expand Up @@ -104,6 +100,8 @@ Step 2: Connecting sensor to gel electrodes
Snap the Muscle BioAmp Patchy on the gel electrodes (Don't peel the plastic backing from the electrodes at this moment).

.. image:: media/patchy-electrode-connection.*
:width: 80%
:align: center

Step 3: Skin Preparation
=============================
Expand Down Expand Up @@ -154,7 +152,7 @@ After opening the serial plotter make sure to select the baud rate to 115200.
Step 7: Visualizing the EMG signals
======================================

Now flex your arm to visualize the muscle signals in real time on your laptop.
Now flex your arm to visualize the muscle signals in real-time on your laptop.

.. image:: media/patchy-emg.*

Expand Down
Binary file modified hardware/bioamp/muscle-bioamp-patchy/media/kit-contents.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
2 changes: 1 addition & 1 deletion hardware/bioamp/muscle-bioamp-shield/index.rst
Original file line number Diff line number Diff line change
Expand Up @@ -115,7 +115,7 @@ Before you start using the kit, please download `Arduino IDE v1.8.19 (legacy IDE

.. image:: ../../../kits/diy-neuroscience/basic/media/arduino-ide.png

Assemblying the Kit
Assembling the Kit
********************

You can get your own Muscle BioAmp Shield bag of parts from our `online stores <https://linktr.ee/Upside_Down_Labs_stores>`_ (shipping worldwide)
Expand Down
Binary file modified media/bioamp-exg-pill.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file modified media/bioamp-v1.5.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file modified media/muscle-bioamp-biscute.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file modified media/muscle-bioamp-blip.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file modified media/muscle-bioamp-candy.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file modified media/muscle-bioamp-patchy.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file modified media/muscle-bioamp-shield.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.

0 comments on commit 91a1877

Please sign in to comment.