Glass-App is an implementation of the neic-glass3 libraries that reads input from a file system directory, and writes output to a file system directory, with a static stationlist and configuration.
To build glass-app, set the BUILD_GLASS-APP
option equal to true (1) in the cmake command or GUI.
An example configuration for glass-app is available in the glass-app params directory
{
"Cmd":"Glass",
"LogLevel":"debug",
"ConfigDirectory":"./params",
"InitializeFile":"glass_initialize.d",
"StationList":"stationlist.d",
"GridFiles":[
"glass_ak_grid.d",
],
"InputConfig":"glass_input.d",
"OutputConfig":"glass_output.d"
}
- LogLevel - Sets the logging level, trace, debug, info, warning, error, criticalerror
- ConfigDirectory - Path to directory containing the other glass subcomponent configuration files
- InitializeFile - Configuration file containing the GLASS3 Algorithm configuration
- StationList - File containing the initial GLASS3 station list
- GridFiles - One or more files defining detection grids
- InputConfig - Configuration file containing the input configuration
- OutputConfig - Configuration file containing the output configuration
{
"Configuration":"GlassInput",
"InputDirectory":"./input",
"ErrorDirectory":"./error",
"ArchiveDirectory":"./archive",
"Format":"gpick"
"QueueMaxSize":1000,
"ShutdownWhenNoData":true,
"ShutdownWait":300,
"DefaultAgencyID":"US",
"DefaultAuthor":"glassConverter"
}
- InputDirectory - The directory to read input files from
- ErrorDirectory - The optional directory to archive erroneous input files to.
- ArchiveDirectory - The optional directory to archive input files to.
- Format - The format to accept. glass-app currently understands the gpick, jsonpick, jsonhypo, and ccdata (dat) formats
- QueueMaxSize - The maximum size of the input queue
- ShutdownWhenNoData - Optional Flag indicating whether to shut down when there is no more input data
- ShutdownWait - The time in seconds to wait before shutting down due to there being no input data
- DefaultAgencyID - The default agency identifier to use when converting data to json
- DefaultAuthor - The default author to use when converting data to json
{
"Configuration":"GlassOutput",
"PublicationTimes":[20,180],
"PublishOnExpiration":true,
"OutputDirectory":"./output",
"OutputFormat":"json",
"TimeStampFileName":true,
"OutputAgencyID":"US",
"OutputAuthor":"glass"
}
- PublicationTimes - The time(s), in seconds since the detections was first found, to publish
- PublishOnExpiration - Flag indicating whether to always publish a final version of a detection when it expires out of glass
- OutputDirectory - The directory to write output to
- OutputFormat - The format to write output in for now, the only format is json
- TimeStampFileName - Optional flag to define whether to timestamp output file names, defaults to true
- OutputAgencyID - The agency identifier to use when generating output data
- OutputAuthor - The author to use when generating output data
For neic-glass3 algorithmic configuration, see GLASS 3 Configuration.
To run glass-app, use the following command: glass-app <configfile> [noconsole]
where <configfile>
is the required path the the glass.d configuration file and [noconsole]